Changes in Corneal Biomechanical Properties after Artiflex® and Visian® ICLV4c Implantation Using Scheimpflug-Based Noncontact Tonometer: A Comparative Analysis

Authors

  • Ana Marta Department of Ophthalmology, Centro Hospitalar Universitário do Porto, Oporto, Portugal
  • Catarina Castro Department of Ophthalmology, Centro Hospitalar Universitário do Porto, Oporto, Portugal
  • Ana Carolina Abreu Department of Ophthalmology, Centro Hospitalar Universitário do Porto, Oporto, Portugal
  • Sílvia Monteiro Department of Ophthalmology, Centro Hospitalar Universitário do Porto, Oporto, Portugal
  • Maria Céu Pinto Department of Ophthalmology, Centro Hospitalar Universitário do Porto, Oporto, Portugal

DOI:

https://doi.org/10.48560/rspo.25904

Keywords:

Biomechanical Phenomena, Cornea, Lens Implantation, Intraocular/adverse effects, Phakic Intraocular Lenses, Refractive Surgical Procedures

Abstract

INTRODUCTION : Our purpose was to compare changes in biomechanical properties after Artiflex® and Visian® ICLV4c implantation.

METHODS: A prospective, nonrandomized, comparative, interventional case series study with corneal biomechanical evaluation by an ultra-high-speed Scheimpflug imaging during non-contact tonometry (Corvis ST, OCULUS®).

RESULTS: The study included 38 eyes: 23 Artiflex-treated eyes and 15 implantable collamer lens (ICL)-treated eyes. The average age at surgery and the mean follow-up time were similar between groups (p=0.170 and p=0.252, respectively). Artiflex- and ICL-treated eyes showed a significantly stiffer behaviour in 12/28 and 4/28 of first and in 5/11 and 1/11 of second generation biomechanical corneal parameters compared to preoperative values, respectively. Both groupsshowed a softer behaviour in the same only 2/28 of first generation parameters. Comparing Artiflex- and ICL-treated eyes, the “PachySlope” was the only postoperative parameter that differed between groups, but the difference already exists in preoperative evaluation. All biomechanical parameters had a similar or less proportion of eyes within ectasia susceptibility interval at post-operative in both Artiflex- and ICL-treated eyes. There was a significant increase of intraocular pressure (evaluated by different methods, all with p<0.05) in Artiflex-treated eyes after surgery, compared to preoperative values.

CONCLUSION: Overall it seems that there is an increase in corneal resistance after both phakic intraocular lens implantation (supported by less proportion of eyes within ectasia susceptibility interval at postoperative) or in aqueous humour resistance. The effect seems to be higher in Artiflex-treated eyes because of more postoperative biomechanical parameters changed and higher IOP (evaluated by different methods) than ICL-treated eyes, when comparing the pre and postoperative period. These findings support the safety of these surgical options for the correction of the refractive error of eyes with contraindications to laser ablation from a biomechanical viewpoint.

Downloads

Download data is not yet available.

References

Helgason G. Choosing Among LASIK,Phakic IOLs,and Clear Lens Extraction [Internet]. CRSTEurope. 2010 [cited 2021 Sep 11]. Available from: https://crstodayeurope.com/articles/2010- nov/choosing-among-lasikphakic-iolsand-clear-lens-extraction/

Espandar L, Meyer JJ, Moshirfar M. Phakic intraocular lenses. Curr Opin Ophthalmol. 2008;19:349–56. doi: 10.1097/ ICU.0b013e3283009f0a.

Kamiya K, Igarashi A, Shimizu K, Matsumura K, Komatsu M. Visual performance after posterior chamber phakic intraocular lens implantation and wavefront-guided laser in situ keratomileusis for low to moderate myopia. Am J Ophthalmol. 2012;153:1178-1186.e1. doi: 10.1016/j.ajo.2011.12.005.

Colin J, Mimouni F, Robinet A, Conrad H, Mader P. The surgical treatment of high myopia: comparison of epikeratoplasty, keratomileusis and minus power anterior chamber lenses. Re- fract Corneal Surg. 1990;6:245–51.

Fechner PU, van der Heijde GL, Worst JG. The correction of myopia by lens implantation into phakic eyes. Am J Ophthal- mol. 1989;107:659–63.

Hoyos JE, Dementiev DD, Cigales M, Hoyos-Chacón J, Hoffer KJ. Phakic refractive lens experience in Spain. J Cataract Refract Surg. 2002;28:1939–46. doi: 10.1016/s0886-3350(02)01439-6.

Karimian F, Baradaran-Rafii A, Hashemian SJ, Hashemloo A, Jafari ME, Yaseri M, et al. Comparison of Three Phakic Intraocular Lenses for Correction of Myopia. J Ophthalmic Vis Res. 2014;9:427–33. doi: 10.4103/2008-322X.150805.

Baptista PM, Marta AA, Marques JH, Abreu AC, Monteiro S, Menéres P, et al. The Role of Corneal Biomechanics in the As- sessment of Ectasia Susceptibility Before Laser Vision Correction. Clin Ophthalmol. 2021;15:745–58. doi: 10.2147/OPTH. S296744.

Roberts C. Biomechanics of the cornea and wavefront-guided laser refractive surgery. J Refract Surg. 2002;18:S589-92. doi: 10.3928/1081-597X-20020901-18.

Kamiya K, Miyata K, Tokunaga T, Kiuchi T, Hiraoka T, Oshika T. Structural analysis of the cornea using scanning-slit corneal topography in eyes undergoing excimer laser refractive surgery. Cornea. 2004;23:S59-64. doi: 10.1097/01. ico.0000136673.35530.e3.

Esporcatte LP, Salomão MQ, Lopes BT, Vinciguerra P, Vinciguerra R, Roberts C, et al. Biomechanical diagnostics of the cornea. Eye Vis. 2020;7:9. doi: 10.1186/s40662-020-0174-x

Gokhale NS, Sawhney S. Reduction in Astigmatism in Manual Small Incision Cataract surgery through Change of Incision Site. Indian J Ophthalmol. 2005;53:201-3. doi: 10.4103/0301- 4738.16684.

Nikose AS, Saha D, Laddha PM, Patil M. Surgically induced astigmatism after phacoemulsification by temporal clear corneal and superior clear corneal approach: a comparison. Clin Ophthalmol. 2018;12:65-70. doi: 10.2147/OPTH.S149709.

Ali M, Kamiya K, Shimizu K, Igarashi A, Ishii R. Clinical evaluation of corneal biomechanical parameters after posterior chamber phakic intraocular lens implantation. Cornea 2014;33:470–4. doi: 10.1097/ICO.0000000000000088.

Li K, Wang Z, Zhang D, Wang S, Song X, Li Y, et al. Visu- al outcomes and corneal biomechanics after V4c implantable collamer lens implantation in subclinical keratoconus. J Cataract Refract Surg. 2020;46:1339–45. doi: 10.1097/j.

jcrs.0000000000000262.

Downloads

Published

2022-09-30

How to Cite

Marta, A., Castro, C., Abreu, A. C., Monteiro, S., & Pinto, M. C. (2022). Changes in Corneal Biomechanical Properties after Artiflex® and Visian® ICLV4c Implantation Using Scheimpflug-Based Noncontact Tonometer: A Comparative Analysis. Revista Sociedade Portuguesa De Oftalmologia, 46(3), 131–140. https://doi.org/10.48560/rspo.25904

Issue

Section

Original Article