Intraocular Lens Power Calculation After Double Keratorefractive Procedures: A Case Series

Authors

DOI:

https://doi.org/10.48560/rspo.32821

Keywords:

Biometry, Keratomileusis, Laser In Situ, Keratotomy, Radial, Lenses, Intraocular, Photorefractive Keratectomy

Abstract

INTRODUCTION: Our purpose was to report the results of intraocular lens (IOL) power calculation in patients who received two sequential keratorefractive procedures.
METHODS: Biometry data were collected using IOL Master 500 and 700. Formulas available at the American Society of Cataract and Refractive Surgery (ASCRS) online calculator, PEARL-DGS and Emmetropia Verifying Optical (EVO) formulas were used.
RESULTS: Seven eyes of 6 myopic patients were enrolled. Six eyes have been submitted to radial keratotomy (RK) and laser-assisted in situ keratomileusis (LASIK) and one eye had a history of RK followed by a photorefractive keratectomy (PRK). The ASCRS formulas and PEARL-DGS for prior RK conditions were found to have the greater predictability for patients with 8 or more RK. For those with only 4 RK, the most predictable formulas were those from ASCRS for prior myopic LASIK/PRK condition and EVO and PEARL-DGS formulas.
CONCLUSION: The IOL power calculation for patients with history of keratorefractive surgery remains a challenging and there is still lack of evidence and consensus for these scenarios.

Downloads

Download data is not yet available.

References

Klein BE, Klein R, Lee KE, Gangnon RE. Incidence of age-related cataract over a 15-year interval the Beaver Dam Eye Study. Ophthalmology. 2008;115:477-82. doi:10.1016/j.ophtha.2007.11.024

Patel RH, Karp CL, Yoo SH, Amescua G, Galor A. Cataract Surgery After Refractive Surgery. Int Ophthalmol Clin. 2016;56:169-80. doi:10.1097/IIO.0000000000000106

Gimbel HV, Sun R. Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis. J Cataract Refract Surg. 2001;27:571-6. doi:10.1016/s08863350(00)00795-1

Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000;238:765-73. doi:10.1007/s004170000188

Shammas HJ, Shammas MC, Hill WE. Intraocular lens power calculation in eyes with previous hyperopic laser in situ keratomileusis. J Cataract Refract Surg. 2013;39:739-44. doi:10.1016/j.jcrs.2012.11.031

Barrett GD. An improved universal theoretical formula for intraocular lens power prediction. J Cataract Refract Surg. 1993;19:713-20. doi:10.1016/s0886-3350(13)80339-2

Awwad ST, Kilby A, Bowman RW, Verity SM, Cavanagh HD, Pessach Y, McCulley JP. The accuracy of the double-K adjustment for third-generation intraocular lens calculation formulas in previous keratorefractive surgery eyes. Eye Contact Lens. 2013;39:220-7. doi:10.1097/ICL.0b013e31828af126

Ferguson TJ, Randleman JB. Cataract surgery following refractive surgery: Principles to achieve optical success and patient satisfaction. Surv Ophthalmol. 2024;69:140-59. doi:10.1016/j.survophthal.2023.08.002

Turnbull AMJ, Crawford GJ, Barrett GD. Methods for Intraocular Lens Power Calculation in Cataract Surgery after Radial Keratotomy. Ophthalmology. 2020;127:45-51. doi:10.1016/j.ophtha.2019.08.019

Oh R, Hyon JY, Jeon HS. Accuracy of the PEARL-DGS Formula for Intraocular Lens Power Calculation in Post-Myopic Laser Refractive Corneal Surgery Eyes. Am J Ophthalmol. 2024;259:79-87. doi:10.1016/j.ajo.2023.10.020

Wang L, Koch DD, Hill W, Abulafia A. Pursuing perfection in intraocular lens calculations: III. Criteria for analyzing outcomes. J Cataract Refract Surg. 2017;43:999-1002. doi:10.1016/j.jcrs.2017.08.003

Liu CF, Sun CC, Lin YH, Peng SY, Yeung L. Intraocular lens power calculation after radial keratotomy and LASIK - A case report. Am J Ophthalmol Case Rep. 2019;15:100495. doi:10.1016/j.ajoc.2019.100495

Christopher KL, Ifantides C, Lynch AM, Patnaik JL. Intraocular lens calculations in patients with previous sequential radial keratotomy and LASIK/PRK. J Cataract Refract Surg. 2022;48:971-3. doi:10.1097/j.jcrs.0000000000000913

Downloads

Published

2024-11-23

How to Cite

Ferreira, A., Marques, J. H., Silva, N., Abreu, A. C., Monteiro, S., & Pinto, M. do C. (2024). Intraocular Lens Power Calculation After Double Keratorefractive Procedures: A Case Series. Revista Sociedade Portuguesa De Oftalmologia. https://doi.org/10.48560/rspo.32821

Issue

Section

Original Article