Inglês
DOI:
https://doi.org/10.6063/motricidade.31716Palavras-chave:
Physiological responses, Near-infrared spectroscopy, Muscle oxygen saturationResumo
Technological advances in sports allow coaches and researchers to better identify the stimulus-response dose, maximising performance and decreasing the risk of injury (Li et al., 2016). Real-time continuous monitoring of peripheral physiological responses using near-infrared spectroscopy (NIRS) is a promising area, as it reflects the local effort of a specific muscle during and after exercise (Barstow et al., 2019). This study aimed to analyse the effects of six push-up variations on muscle oxygen saturation (SmO2) derived-parameters. Fifteen physically active participants (age = 25.2 ± 3.5 years old; height = 1.76. ± 0.05 m; weight = 75.9 ± 9.1 kg; triceps brachii (TB) skinfold thickness = 10.8 ± 3.4 mm; deltoideus medius (DM) skinfold thickness = 10.6 ± 2.6 mm) completed the experimental study design which comprised two sessions: in the first session the participants performed a familiarisation with the protocol procedures, and in the second session they performed the six push-up variations in random order. The six push-up variations included 1) diamond, 2) declined, 3) inclined, 4) knuckles with one foot, 5) spartans, and 6) unstable terra-core platform. All exercises were performed for 1 minute, with a 5-minute recovery time in between. Two NIRS devices (MOXY, Fortiori Design LLC, Minnesota, USA) were placed on the TB and DM muscles to measure SmO2 during the session. Average value of SmO2 (SmO2avg), amplitude of deoxygenation (SmO2 deoxy) and recovery time to baseline value (SmO2reoxy) were determined. Comparisons between the six variations of the push-up exercise were performed using one-way repeated measures ANOVA, followed by the Bonferroni post hoc pairwise comparisons. The significance level was p<0.05, and all analyses were performed using the Jamovi Project (Computer Software Version 2.3.28, 2022). The SmO2deoxy in TB (Average of 60.9%), F(5,60)=2.18, p=0.069, η2=0.069, and in DM (Average of 42.1%), F(5,70)=2.55, p=0.068, η2=0.05 were not statistically different between push-up variations. Similarly, no significant differences in SmO2avg and SmO2 reoxy were observed between variations in both muscle groups, indicating that these exercise variations show identical behaviour. The results of this study show that the analysed SmO2 derived-parameters did not differ significantly, presenting a similar balance of oxygen supply and consumption. This may be attributed to the exercise variations which have little muscle mass in dynamic contraction and is very localised. The manipulation of exercise conditions in real-time with NIRS technology makes it possible to analyse localised muscle response and thus maximise athlete performance.
Downloads
Publicado
Edição
Secção
Licença
Os autores dos manuscritos submetidos para publicação deverão ceder, a título integral e permanente, os direitos de autor (copyright) à revista Motricidade e às Edições Desafio Singular. A cedência de direitos de autor permite a publicação e divulgação do artigo em formato impresso ou eletrónico e entrará em vigor a partir da data de aceitação do manuscrito. Os autores concedem, ainda, os direitos para a revista Motricidade utilizar e explorar o respetivo artigo, nomeadamente para licenciar, ceder ou vender o seu conteúdo a bases de resumos/indexação ou outras entidades.
Nos termos da licença “Creative Commons”, os autores poderão reproduzir um número razoável de exemplares para uso pessoal ou profissional, mas sem fins comerciais. Nos termos da licença SHERPA/RoMEO, os autores poderão, ainda, disponibilizar/arquivar uma cópia digital final (versão postprint) do artigo no seu website ou no repositório científico da sua instituição.