Reproducibility of the dynamic balance test of lower limbs with reduction of the body weight in individuals with knee osteoarthritis
DOI:
https://doi.org/10.6063/motricidade.27173Palavras-chave:
Knee Osteoarthritis, Balance Test, ReproducibilityResumo
The dynamic balance of the lower limbs has shown great importance in accomplishing activities of daily living, especially for walking and maintenance in the orthostatic position. In this context, individuals with knee osteoarthritis have changes in their physical capacity, mainly due to joint changes and muscular wear. The instrument called OctoBalance® is one of the most used to evaluate this balance, which analyses four different executions of movement in the limbs. However, individuals with knee osteoarthritis cannot perform this evaluation due to the need for single limb support during movements. This study aimed to verify whether it is reproducible to perform the dynamic balance evaluation of lower limbs with a reduction of 10% of body weight through a suspension system. A cross-sectional study was carried out with 2 collections with a 48-hour interval between them, using the Lower Body Test performed with OctoBalance®. The dynamic balance test followed the protocol of 3 repetitions observing the learning factor and then 3 repetitions where the values were collected, with the suggested adaptation for all 4 diagonals in both limbs. The interclass correlation index (ICI), coefficient of variation (CV), estimative standard error (EEE) and minimum detectable difference (MDD) were calculated as indicators of reproducibility. Also, Bland-Altman Graphs were used for visual verification of the agreement between the means. Results: The reliability tests showed a very high interclass correlation through the ICI and low variation values for all the movements evaluated through the CV. The EEE and MDD calculations showed positive responses for greater reliability, and the Bland-Altman graphs showed an agreement between the means. Reproducibility was positive for the Lower Body Test with the Octobalance® platform for the evaluation of lower limb dynamic balance in women with knee osteoarthritis.
Downloads
Publicado
Edição
Secção
Licença
Os autores dos manuscritos submetidos para publicação deverão ceder, a título integral e permanente, os direitos de autor (copyright) à revista Motricidade e às Edições Sílabas Didáticas. A cedência de direitos de autor permite a publicação e divulgação do artigo em formato impresso ou eletrónico e entrará em vigor a partir da data de aceitação do manuscrito. Os autores concedem, ainda, os direitos para a revista Motricidade utilizar e explorar o respetivo artigo, nomeadamente para licenciar, ceder ou vender o seu conteúdo a bases de resumos/indexação ou outras entidades.
Nos termos da licença “Creative Commons”, os autores poderão reproduzir um número razoável de exemplares para uso pessoal ou profissional, mas sem fins comerciais. Nos termos da licença SHERPA/RoMEO, os autores poderão, ainda, disponibilizar/arquivar uma cópia digital final (versão postprint) do artigo no seu website ou no repositório científico da sua instituição.